Description
Filtercube
TEKA
FILTERCUBE 2N / 2H central filter units
Product Specification
Is the Filtercube certified?
The Filtercube product line is certified according to the standard DIN EN ISO 15012-1 and according to the BGIA (Berufsgenossenschaftliches Institut für Arbeitsschutz – Institute for occupational safety and health) concerning dangerous substances. It is approved for the welding fume category W3 as stationary filter unit for welding fume extraction.
For which fields can the Filtercube be applied?
– as central suction unit for several manual welding posts
– as suction unit for welding robots
– as suction unit for flame cutting tables or grinding benches
– as suction unit for room exhausting (Push-Pull-systems)
– as suction unit combined with exhausting tables
– as mobile filter units for shipyards (special design)
– as suction unit for grinding of non explosive materials
What else do you have to respect?
Many types of dust, for example welding dust particles, are inflammable if ignition sources are let in. The user has to avoid these specific risks. He has to take care especially that no ignition sources are aspired during operation of the unit. Concerning explosive substances, please ask for a separate offer according to ATEX.
Units for room exhausting do not absolve the operator from providing appropriate personal protection equipment for his staff.
What is included in delivery?
You receive a complete system that is ready for operation including the necessary star-delta connection (from 5,5 kW on). You only have to accomplish the electrical connection on site.
How is the Filtercube constructed?
The main parts of the Filtercube are the ventilator with silencer, pneumatic housing, filter section including cartridges and dust collecting section as well as the control element Pulse Control.
The housing consists of a stable steel plate construction and is provided with powder coating to enable an optimal and rapid maintenance. The maintenance door of the filter cartridge housing is equipped with a vision panel that consists of laminated safety glass. The Pulse Control is delivered completely preset and is very easy to handle. The control element is specially developed to survey and control the filter unit. All functions can be recalled via a multifunction button and adjusted according to the operation parameters. The Filtercube is equipped with filter cartridges of the filter category BIA M. A special auxiliary filtering substance is coated on these cartridges ex works.
Optionally available (with BGIA certification)
– Continuous precoating device
– Particle sensor
Optionally available (without BGIA certification)
– Activated carbon extension set
TECHNICAL DATA:
Max. volumetric flow of the fan [m³/h]: | 2.500 |
Max. pressure [Pa]: | 2.900 |
Pre-filter: | Baffle plate made of copper |
Main-filter: | Filter cartridge |
Engine performance [kW]: | 1,5 |
Voltage [V]: | 400 |
Power Frequency [Hz]: | 50 |
Current consumption [A]: | 3,5 |
Control voltage [V]: | 230 |
Power Frequency of control [Hz]: | 50 |
Current consumption of control [A]: | 0,3 |
Sound level [dB(A)]: | 74 |
Weight [kg]: | 180 |
Height [mm]: | 2.070 |
Depth [mm]: | 983 |
Width [mm]: | 665 |
Filter control: | Pulse Control steering |
Separation efficiency [%]: | ≥ 99 |
SPARE PARTS:
Filter cartridge 7,8 m²
Separation efficiency: BGIA M, filter surface: 7,8 m²
Kit of 10 bags for dust collecting drawer
Dust collecting bags for the suction units STRONGMASTER, CARTMASTER and FILTERCUBE 2
Precoat for filter cartridges packing unit 10 kg
With precoating the cartridge`s lifetime increases considerably
Precoat for filter cartridges packing unit 2 x 0,5 kg
With precoating the cartridge`s lifetime increases considerably
ACCESSORIES:
Filter cartridge, 10 m²
Separation efficiency: BGIA M, filter surface: 10m²
Filter cartridge 12,5 m², type easy clean +
Separation efficiency: BGIA M, filter surface: 12,5 m²